Menu

TRVZB

Product Overview

Introduction

Product Name

SONOFF Zigbee Thermostatic Radiator Valve

Product Model

TRVZB

With the SONOFF Thermostatic Radiator Valve, you can control and reach the temperature you want more accurately. It allows remote control and timing. The window opening detection function helps you save energy and avoid additional energy waste. The matching adapters can be installed on almost any valve.

Highlights

  • Smart Control
    SONOFF Zigbee Thermostatic Radiator Valve supports full smart functions, including remote control via app, voice commands, scheduling, and group management.
  • Open Window Detection
    Automatically shuts off the radiator during ventilation to prevent energy waste.
  • Zigbee 3.0 Standard Compatible
    Compatible with Zigbee 3.0 hubs such as SONOFF iHost, NSPanel Pro, ZB Bridge Pro, ZBDongle-P, and ZBDongle-E, as well as any Zigbee 3.0-compliant hubs.
  • Broad Heating System Compatibility
    Fits standard 'M30 x 1.5mm' radiator valves; includes adapters compatible with most heating systems and manufacturers.
  • Comprehensive Features
    Child lock prevents accidental changes by kids. Frost protection avoids pipe freezing and bursting. Supports 6 months of historical data, enabling you to optimize heating schedules based on usage trends.

Applications

  • Room-by-room heating control: set individual temperatures per radiator—for example, raise bedroom temp to 22 °C in the morning and reduce to 18 °C at night.
  • Energy savings & automation: open-window detection stops heating when a window is opened; schedule heating only when needed.

Specification

Model

TRVZB

Input

4.5V (3x1.5V AA Batteries)

Battery model

1.5V LR6 Alkaline AA Battery

Wireless connection

Zigbee 3.0

Threaded connection

M30x1.5mm

Temperature setting range

4℃-35℃

Working temperature

0℃-60℃

Working humidity

5%-95% RH Non-condensing

Color

White

Casing material

PC

Product dimension

58.4x58.4x94mm

Disconnection means

Type 1B

Pollution degree

2

Rated impulse voltage

500V

Key Features

eWeLink Platform

Notice:

This functionality is available only when the device is paired with the eWeLink app. For capabilities when the device is paired via Matter with Alexa, Google Home, or other platforms, refer to Key Features >> Compatible Zigbee Hubs List

Device Home Page Functions

Key Features

Feature Description

Device Status

Current operating status of the device:

  • Heating
  • Standby

Temp.

The temperature detected by the device.

Battery level

The current battery level of the device.

Manual Temp. Adjustment

Set the target temperature for scheduled or maintained heating.

Operation Mode

Switch the current working mode of the device:

  • Manual
  • Auto
  • Anti-freeze Mode

Smart Schedule

Set heating time periods within a 24-hour day for the device, including:

  • Time Setting
  • Add an interval

Statistics

Records of device status changes.

Device Settings

Key Features

Feature Description

Third-party Platforms

Alexa

Set or query the working mode and temperature.

Google Home

Set or query the working mode and temperature.

SmartThings

Set the working mode and temperature.

Alice

Set or query the working mode and temperature.

IFTTT

Trigger: Current Temperature, Thermostat status
Action: Turn on or off Thermostat, Change Thermostat Mode, Set temperature

Assign location

Set up the home and room where the device is located.

Create Group

After multiple devices are created into a group, you can synchronize all devices in the group.

Temp. Calibration

The temperature readings of the device can be adjusted for calibration.

Child Lock

When enabled, the device knob will be disabled to prevent accidental operation by children. Control is only available through the app.

  • On
  • Off

Open Windows Detection

When enabled, the device operates based on the following logic:

  • If a window is detected open (sudden temperature drop), the valve will automatically close.
  • If the window is detected closed (temperature increases by more than 1.5°C within 4.5 minutes), the valve will automatically reopen.

Anti-freeze Mode

Modify the temperature threshold for Anti-freeze Mode.

Temp. Display from External Sensor

Select another temperature sensor under the same eWeLink account as the temperature reference for the valve.

*Now support: SNZB-02, SNZB-02D, SNZB-02P

Valve Opening Percentage

Adjust the valve opening or closing percentage:

  • Valve Opening (%): 0–100%
  • Valve Closing (%): 0–100%

Smart Scene

Trigger Condition

  • Click
  • Double-Click
  • Long Press

Execution Action

Unsupport being the smart scene execution device.

Delete Device

Remove the device from the eWeLink platform.

Compatible Zigbee Hubs List

Platform

eWeLink

Home Assistant via ZHA

Home Assistant via Z2M

Alexa

SmartThings

Zigbee Hub

ZBBridge

ZBBridge-P

ZBBridge-U,

NSPanel Pro,

iHost

ZBDongle-P/-E

ZBDongle-P/-E

Amazon Echo (Plus 2nd, Echo 4th, Show 2nd)

Samsung SmartThings Hub V3 / Aeotec V3

Operation Mode

Manual Temp. Adjustment

×

×

×

Temp. Calibration

×

×

×

×

History Record

×

Local Scene

×

×

OTA

×

×

×

Notice:

  • If the device fails to be added to the above Zigbee gateway, please update the gateway to the latest version.
  • Philips gateway, IKEA gateway, and Fritzbox gateway are not supported.

Installation and Configuration Guide

Middle button

Rotary knob

③ Auto Mode

④ Heating indicator

Target temperature

Internet connection

Low battery

Configuration key (under the dismountable shell)

Heating valve interface

⑩ Battery case latch

Screen display and introduction

Screen display

Introduction

Window opening function

The device will automatically identify whether the window is opened after you enter the app interface to enable the window opening detection function. When cold air is detected and the temperature drops more than 1.5 °C within 4.5 minutes, the window opening function will be enabled. Alongside the enabling of the function, the screen displays “OP” and the temperature is set at 12 °C.

Note: After the window opening function is enabled, the following operations will disable the window opening function:

1. Temperature setting operation on App or device

2. Temperature rises by more than 1.5℃ within 4.5 minutes

3. No operation on App or device within 30 minutes.

Anti-calcification function

The temperature control valve will perform a routine calcium removal operation at 12:00 am every Monday to prevent calcification of the valve. During the operation, the screen will display "CA".

Child lock function

Press “Middle button” for 3 seconds, then the screen will display “LC”, with child lock enabled. After the screen is locked, press “Middle button” for 3 seconds, then the “LC” on the screen will disappear, with child lock disabled.

When heating is not needed in winter, turn knob counterclockwise    to the “OF” icon, then the device valve is closed and the antifreeze function is enabled.

 

Note: After the antifreeze function is enabled when the room temperature is below 5 °C, the function will be enabled to prevent the radiator from being damaged by freezing. The function will be disabled when the room temperature exceeds 7 °C.

Low battery (Battery needs to be replaced with a new one within 1 week)

Power On the Device

① Press the battery compartment latch while taking out the shell.

② Load the battery.

③ After powering on, the screen displays  and flashes.

Installation

When  stops flashing, install the device to the valve interface.

 

If the screen displays "F5 " or " Ad ", press the middle button and  will display again.

Device Debugging

Short press the middle button, and " Ad" will flash (Figure ①).

Wait for about 5 seconds, and the device will display the initialization interface (Figure ②), which means that debugging is completed.

Add Device

eWeLink Platform

Download the eWeLink App & Add SONOFF Zigbee Gateway.

Open eWeLink to scan the QR code on the Quick Guide or the device itself to add the device.

In manual mode, turn the knob counterclockwise. When the screen displays " OF ", press and hold the middle button for 3 seconds and the screen icon  flashes. Now the device enters Pairing mode, then open the App and add the device in the gateway homepage.

If the device fails to pair with the gateway within 3 minutes after it enters Pairing mode, the device will exit the pairing status. If you want to pair again, please press and hold the middle button for 3 seconds until the icon " OF" flashes when the screen shows .

Compatible Third-party Platform

If you're using a third-party Zigbee gateway, please refer to the corresponding app for detailed instructions on how to add the device.

Temperature Control Mode

The device supports auto mode and manual mode. Shortly press "Middle button" to switch between the two modes.

  • Auto mode: When is displayed on screen, it means the auto mode is on.
  • ② Manual mode: When disappears on screen, it means the manual mode is on.

*Device pairing operation must be done in manual mode.

Screen display rotation

① Dismount the shell

② Press "Configuration key" for 3 seconds to change the screen display direction. 

Factory Reset

Press "Middle button" for a longer time and at the same time put batteries in, then the screen displays "FA" and blinks for 3 seconds. After that, the device is reset to factory settings and is automatically restarted.

Note: All previous settings will be removed after the device is reset to factory settings.

Error Codes, Problems and Solutions

Error code

Problem

Solution

F0

Abnormal temperature sensor

Contact the after-sales staff

F1

Slow valve operation

Check the installation status and heating valve

F2

Excessively wide adjustment range

Check whether the temperature controller is fastened

F3

Excessively small adjustment range

Check the heating valve

F4

The battery runs out

Replace battery

F5

No valve detected

Check whether the valve is installed

FAQ

  1. How to check if my valve is suitable for TRVZB?
    Please refer to the following document to check valve compatibility:
    https://sonoff.tech/wp-content/uploads/2024/12/SONOFF_TRV-Compatibility-Guide-20241202.pdf
  2. What is the battery life of the device?
    TRVZB does not come with batteries in the package; you need to purchase three 1.5V AA batteries separately. The device's battery life depends on factors such as battery capacity and usage environment. Ordinary batteries can generally last for more than six months.
  3. The controlled temperature is inaccurate, always too low/high?
    Possible causes are as follows:
  • The device is installed on a hot water valve, and the temperature measured by the device is easily affected by the water temperature, causing it to be too high. In this case, consider calibrating the temperature value.
  • If the thermostatic valve is far from the usual activity area, consider using an external temperature source to detect the target temperature.
  1. Can rechargeable batteries be used?
    AA rechargeable batteries (e.g., nickel-metal hydride) have a voltage of only 1.2V. When three are connected in series, the voltage is slightly higher than the minimum operating voltage of the device, but even fully charged, they cannot maintain long-term use.

Troubleshooting

  1. Can't turn off the water valve?
    Please check if an adapter is used.
    If an adapter is used, first verify whether the adapter is suitable. Use tools (do not use hands to avoid scalding) to press the adapter and check if the water valve can be closed completely.
    If no adapter is used or the adapter is verified as usable, remove the calibrated device, adjust the temperature, and observe whether the black cylinder at the bottom moves with the heating state switching.
  • If the cylinder moves, it may indicate the water valve is incompatible (exceeding the maximum pushing force or distance of the device) or the valve is rusted, making it difficult to push.
  • If the cylinder does not move, it may be a valve type not covered by the device's calibration algorithm. Please upgrade the firmware to version 1.1.6 or higher.
  1. Inaccurate battery level display?
    The old firmware has insufficient battery detection accuracy, which may cause abnormal low battery prompts (F4 error) or low battery level reporting. If you encounter this issue, please update to the latest firmware promptly.
  2. ZHA can only adjust the calibration by ±2.5℃ at most?
    This is due to an outdated ZHA version that does not support calibration adjustment in the graphical interface. The 2024.3 version of HA has fixed this issue. After updating to an HA version not lower than 2024.3, you can adjust the calibration by ±7℃ via the slider.

Previous
SWV-BSP/SWV-NH
Next
Solutions